Test Code PBC2 SP100 and GP210 Antibodies, IgG, Serum


Additional Testing Requirements


This is a first line test when primary biliary cholangitis is strongly suspected. It should be ordered in conjunction with AMA / Mitochondrial Antibodies (M2), Serum.



Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1.0 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Secondary ID

620736

Useful For

Evaluating the risk of primary biliary cholangitis in anti-mitochondrial antibody (AMA)-negative patients by identification of Sp100 and gp210 antibodies

 

Estimating risk in AMA-positive patients with incomplete feature of disease

Profile Information

Test ID Reporting Name Available Separately Always Performed
SP100 SP100 Antibody, IgG, S Yes Yes
GP210 GP210 Antibody, IgG, S Yes Yes

Method Name

Enzyme-Linked Immunosorbent Assay (ELISA)

Specimen Type

Serum

Specimen Minimum Volume

0.4 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 21 days
  Frozen  21 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK
Heat-treated specimen Reject

Reference Values

Negative: ≤20.0 Units

Equivocal: 20.1-24.9 Units

Positive: ≥25.0 Units

Interpretation

A positive result for anti-gp210 antibodies or anti-Sp100 antibodies in the setting of chronic cholestasis after exclusion of other causes of liver disease is highly suggestive of primary biliary cholangitis.

Method Description

These tests are intended for the semi-quantitative detection of anti-gp210 or anti-Sp100 antibody of the IgG class in human serum. A purified peptide corresponding to a portion of the gp210 or Sp100 protein is bound to the wells of a polystyrene microwell plate. Pre-diluted controls and diluted patient sera are added to separate wells, allowing any gp210 or Sp100 antibodies present to bind to the immobilized antigen. Unbound sample is washed away, and an enzyme labeled anti-human IgG conjugate is added to each well. A second incubation allows the enzyme labeled anti-human IgG to bind to any patient antibodies, which have become attached to the microwells. After washing away any unbound enzyme labeled anti-human IgG, the remaining enzyme activity is measured by adding a chromogenic substrate and measuring the intensity of the color that develops. The assay can be evaluated spectrophotometrically by measuring and comparing the color intensity that develops in the patient wells with the control in the control wells.(Package inserts: QUANTA Lite gp210 ELISA 708995. INOVA Diagnostics; Rev. 5, 04/2019; QUANTA Lite sp100 ELISA 708990. INOVA Diagnostics; Rev. 3, 12/2018)

Day(s) Performed

Tuesday

Report Available

2 to 8 days

Specimen Retention Time

14 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

83516 x 2

LOINC Code Information

Test ID Test Order Name Order LOINC Value
PBC2 SP100 and GP210 Antibodies, IgG, S 106055-7

 

Result ID Test Result Name Result LOINC Value
SP100 SP100 Antibody, IgG, S 96565-7
GP210 GP210 Antibody, IgG, S 96560-8

Forms

If not ordering electronically, complete, print, and send a Gastroenterology and Hepatology Test Request (T728) with the specimen.

Testing Algorithm

For more information see First-Line Screening for Autoimmune Liver Disease Algorithm.