Test Code LAB9672 Phospholipase A2 Receptor, Immunofluorescence, Serum
Additional Codes
PLA2I
PLA2R
Ordering Guidance
This test can be used in a complementary fashion with a quantitative enzyme-linked immunosorbent assay to confirm a positive result, especially if it is a low-level titer. Since the immunofluorescence is more sensitive, it can also be used to detect or follow patients with low level antibodies not detected by ELISA. Â
Specimen Required
Supplies: Sarstedt Aliquot Tube 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial within 2 hours of collection.
Secondary ID
607367Useful For
Distinguishing primary from secondary membranous nephropathy in patients with low levels of anti-phospholipase A2 receptor (PLA2R) antibodies
Screening for anti-PLA2R antibodies
Monitoring patients with membranous nephropathy at very low antibody titers
Method Name
Indirect Immunofluorescence Assay (IFA)
Specimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 14 days | ||
Ambient | 8 hours |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Reference Values
Negative
Interpretation
According to the manufacturer's package insert, the EUROIMMUN Anti-PLA2R indirect immunofluorescence assay was positive in 77.1% of patients with biopsy proven primary membranous nephropathy (pMN). This corresponds well with published literature that approximately 70% of patients with pMN will have anti-phospholipase A2 receptor antibodies.
Method Description
Diluted patient samples are incubated with combinations of substrates. If the reaction is positive, specific antibodies of classes IgA, IgG, and IgM attach to the antigens. In a second step, the attached antibodies are stained with fluorescein-labelled antihuman antibodies and made visible with a fluorescence microscope.(Package insert: Anti-Phospholipase A2 Receptor (PLA2R) IFA EUROPattern Kit, EUROIMMUN US;V 11/23/2021)
Day(s) Performed
Monday, Wednesday, Friday
Report Available
3 to 7 daysSpecimen Retention Time
7 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
86255
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
PLA2I | PLA2R, Immunofluorescence, S | 82991-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
PLA2I | PLA2R, Immunofluorescence, S | 82991-1 |
Forms
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.