Test Code LAB8936 Bone Marrow Exam, Anatomic Pathology
Test Information
- Bone Marrow Biopsy (light microscopy)
- Includes: H & E and Iron stains; additional stains available upon request
- Specimen: Bone Marrow Biopsy
- Container: Random - Plain Tube, Hematology technologist or resident will place specimen into fixative solution
- Storage: Bone Marrow biopsy placed in fixative by technologist and sent to the biopsy lab. Specimen must remain in fixative for two hours. Specimen must be transferred to 10% formalin following initial fixation in fixative.
- Notes: Call Hematology Lab to schedule biopsy, 792-8634; After hours, page the Laboratory Medicine Resident
Turnaround Time
Performed: Test is performed Monday - Friday; 8:00 AM - 4:00 PM. After hours, page the Anatomic Pathology Resident on-call, 792-0590, Beeper # 17009 or 792-2123
Reported: Results reported in 24 hours. excluding weekends and holidays