Sign in →

Test Code LAB64232 Streptococcus pneumoniae IgG Antibodies, 23 Serotypes, Serum

Additional Codes

PN23M


Ordering Guidance


This test is the preferred test for patients previously tested for Streptococcus pneumoniae serotypes (as part of follow up testing or part of pre/post vaccine assessment).

 

The preferred test for patients being evaluated for possible immunodeficiency or for assessment of pneumococcal vaccination response (initial evaluation) is PNTOR / Streptococcus pneumoniae IgG Antibodies, Total, with Reflex, Serum

 

The preferred test for patients previously tested for total Streptococcus pneumoniae antibodies (as part of follow up testing or part of pre/post vaccine assessment) is PNTO / Streptococcus pneumoniae IgG Antibodies, Total, Serum



Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial 

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into plastic vial


Secondary ID

619921

Useful For

Assessing the IgG antibody response to active immunization with nonconjugated, 23-valent pneumococcal vaccines

 

Assessing the IgG antibody response to active immunization with conjugated 13-valent, 15-valent and 20-valent pneumococcal vaccines

 

Determining the ability of an individual to produce an antibody response to polysaccharide antigens, as part of the evaluation for humoral or combined immunodeficiencies

Method Name

Bead-Based Multiplex Immunoassay

Specimen Type

Serum

Specimen Minimum Volume

0.4 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 21 days
  Frozen  21 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Reference Values

Results are reported in mcg/mL

 

Serotype

Normal value

1 (1)

≥1.0

2 (2)

≥1.0

3 (3)

≥1.0

4 (4)

≥1.0

5 (5)

≥1.0

8 (8)

≥1.0

9N (9)

≥1.0

12F (12)

≥1.0

14 (14)

≥1.0

17F (17)

≥1.0

19F (19)

≥1.0

20 (20)

≥1.0

22F (22)

≥1.0

23F (23)

≥1.0

6B (26)

≥1.0

10A (34)

≥1.0

11A (43)

≥1.0

7F (51)

≥1.0

15B (54)

≥1.0

18C (56)

≥1.0

19A (57)

≥1.0

9V (68)

≥1.0

33F (70)

≥1.0

Interpretation

As a general guideline, nonimmunocompromised adults develop IgG antibodies approximately 4 to 6 weeks following nonconjugated vaccination.

 

Either of the following conditions is consistent with a normal response to Streptococcus pneumonia vaccination:

1. When comparing pre- and post-vaccination samples, antibody concentrations increased by at least 2-fold for

a. >50% of serotypes in children <6 years of age

b. >70% of serotypes for individuals >6 years of age

 

2. In either a pre- or post-vaccination sample, antibody concentrations >/= 1.0 mcg/mL for

a. >50% of serotypes for children <6 years of age

b. >70% of serotypes for individuals >6 years of age

Method Description

IgG antibodies to Streptococcus pneumoniae serotypes are measured by microsphere photometry (also known as bead-based multi-plex immunoassay) using pneumococcal polysaccharides conjugated to MagPlex microspheres.

 

This assay detects IgG antibodies to different serotypes of S pneumoniae. The serotype-specific antibodies bound in the first stage of the assay are detected with R-phycoerythrin-conjugated, anti-human IgG antibody in the second stage of the assay.

 

Pneumococcal polysaccharides are modified with 4-(4,6-dimethoxy[1,3,5]triazin-2-yl)-4-methylmorpholinium chloride (DMTMM) and conjugated to magnetic carboxylated polystyrene microparticles (hereinafter referred to as magnetic beads) that have been dyed into spectrally distinct regions to be identified by the Luminex FlexMap 3D (FM3D) instrument. A mixture of 24 different beads (23 coupled to a different pneumococcal polysaccharide and 1 that is not coupled, to serve as a check for non-specific binding) is prepared in 1% BSA in PBS.

 

Standards and controls are prepared from pools of patient serum that have previously detected antibodies for the 23 serotypes of S pneumoniae. A dilution series of standard, controls, and patient sera are added to a microwell plate.

 

An equal amount of the bead mixture is added and allowed to incubate. The plate is washed using 1% BSA in PBS on a magnetic plate washer to remove unbound material. A substrate containing a reporter molecule, R-phycoerythrin conjugated anti-human IgG antibody, is added to the plate. After incubation, the plate is read on the Luminex FM3D where the magnetic beads are differentiated and quantitated by 2 separate lasers. The red diode laser (635 nm) excites the fluorescent dyes contained within the beads, and the green laser (532 nm) excites the reporter molecule bound to the bead surface. Data reduction software is used to quantify the amount of IgG antibody in unknown samples by correlation to a standard curve using a 5-Parameter Logistic (PL) curve fit.(Unpublished Mayo method)

Day(s) Performed

Monday through Friday

Report Available

4 to 6 days

Specimen Retention Time

3 months

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

86317 x 23

LOINC Code Information

Test ID Test Order Name Order LOINC Value
PN23M S. pneumoniae IgG Ab,23 serotypes,S 42366-5

 

Result ID Test Result Name Result LOINC Value
620316 Serotype 1 (1) 85954-6
620317 Serotype 2 (2) 86039-5
620318 Serotype 3 (3) 86080-9
620319 Serotype 4 (4) 86107-0
620320 Serotype 5 (5) 86130-2
620321 Serotype 8 (8) 86147-6
620322 Serotype 9N (9) 86169-0
620323 Serotype 12F (12) 85977-7
620324 Serotype 14 (14) 85991-8
620325 Serotype 17F (17) 86009-8
620326 Serotype 19F (19) 86024-7
620327 Serotype 20 (20) 86045-2
620328 Serotype 22F (22) 86052-8
620329 Serotype 23F (23) 86064-3
620330 Serotype 6B (26) 27118-9
620331 Serotype 10A (34) 86098-1
620332 Serotype 11A (43) 86122-9
620333 Serotype 7F (51) 25296-5
620334 Serotype 15B (54) 40973-0
620335 Serotype 18C (56) 27395-3
620336 Serotype 19A (57) 40974-8
620337 Serotype 9V (68) 30153-1
620338 Serotype 33F (70) 40969-8
620404 Interpretation 69048-7

Forms

If not ordering electronically, complete, print, and send a General Request (T239) with the specimen.