Test Code LAB2206 Complement, Total, Serum
Additional Codes
COM
Useful For
Detection of individuals with an ongoing immune process
First-tier screening test for congenital complement deficiencies
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Serum RedSpecimen Required
Patient Preparation: Fasting preferred.
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Red top (serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Immediately after specimen collection, place the tube on wet ice.
2. After sample has clotted on wet ice, centrifuge at 4° C and aliquot serum into 5 mL plastic vial.
3. Within 30 minutes of centrifugation, freeze specimen. Sample must be placed on dry ice if not frozen immediately.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum Red | Frozen | 28 days |
Reference Values
30-75 U/mL
Day(s) Performed
Monday through Friday
CPT Code Information
86162
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
COM | Complement, Total, S | 4532-8 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
COM | Complement, Total, S | 4532-8 |
Interpretation
Low levels of total complement (total hemolytic complement) may occur during infections, disease exacerbation in patients with systemic lupus erythematosus, and in patients with immune complex diseases such as glomerulonephritis.
Undetectable levels suggest the possibility of a complement component deficiency. Individual complement component assays are useful to identify the specific deficiency.
Method Description
An automated method is performed using liposomes as the target for the serum complement system. Dinitrophenyl (DNP)-labeled liposomes are sensitized with antibody to DNP. Serum complement causes lysis and release of entrapped glucose-6-phosphate dehydrogenase. Glucose-6-phosphate dehydrogenase reacts with glucose-6-phosphate and nicotinamide adenine dinucleotide (NAD[+]). NAD(+) is then reduced to NADH, and the conversion is measured at 340 nm. The assay correlates with the total complement assay based on sheep red blood cell lysis, has lower variability, and is simpler to perform.(Package insert: Fujifilm Autokit CH50. Fujifilm Wako Pure Chemical Corporation; 04/2018; Yamamoto S, Kubotsu K, Kida M, et al. Automated homogeneous liposome-based assay system for total complement activity. Clin Chem. 1995;41(4):586-590)
Report Available
1 to 2 daysSpecimen Retention Time
14 daysReject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Method Name
Automated Liposome Lysis Assay