Sign in →

Test Code LAB2118 Soluble Transferrin Receptor (sTfR), Serum

Additional Codes

STFR

Useful For

Evaluation of suspected iron deficiency in patients who may have inflammation, infection, or chronic disease and other conditions in which ferritin concentration does not correlate with iron status, including:

-Cystic fibrosis patients who frequently have inflammation or infections(2-3)

-Evaluating insulin-dependent diabetics who may have iron-deficiency resulting from gastric autoimmunity and atrophic gastritis(4)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions:

1. Serum gel tubes should be centrifuged within 2 hours of collection.

2. Red-top tubes should be centrifuged, and the serum aliquoted into a plastic vial within 2 hours of collection.


Specimen Minimum Volume

0.25 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Frozen (preferred) 90 days
  Refrigerated  7 days
  Ambient  72 hours
Medical University of South Carolina Note:

On-campus collections: Tube to 99 or deliver to University Extension Hospital Room EH318 
Submission Container/Tube: Plastic vial, Frozen
 
Off-campus collections: Centrifuge and aliquot within 2 hours. Specimen to be stored/transported FROZEN.

Reference Values

1.8-4.6 mg/L

It is reported that African Americans may have slightly higher values.

Day(s) Performed

Monday through Sunday

CPT Code Information

84238

LOINC Code Information

Test ID Test Order Name Order LOINC Value
STFR Soluble Transferrin Receptor (sTfR) 30248-9

 

Result ID Test Result Name Result LOINC Value
STFR Soluble Transferrin Receptor (sTfR) 30248-9

Interpretation

Soluble transferrin receptor (sTfR) concentrations are inversely related to iron status; sTfR elevates in response to iron deficiency and decreases in response to iron repletion.

Method Description

Latex-bound anti-sTfR antibodies react with the antigen in the sample to form an antigen/antibody complex. Following agglutination, the complex is measured turbidimetrically on a Roche P Modular.(Package insert: The Tina-quant Soluble Transferrin Receptor Immunoturbidimetric assay for the in vitro quantitative determination of soluble transferrin receptor. Roche Corporation; V 2, 01/2021)

Report Available

Same day/1 to 2 days

Specimen Retention Time

1 week

Reject Due To

Gross hemolysis Reject

Method Name

Immunoturbidimetric Assay

Secondary ID

84283