Test Code LAB1973 HHV6 qPCR (Plasma)
Additional Codes
HHV-6 BY PCR, QUANT, BLOOD
Test ID: 6500
Collection:
Specimen: Blood
Container:
- Collect 4-5 mL whole blood in EDTA or ACD tube.
- Avoid using gel separator tubes; samples collected in gel separator tubes have increased rate of PCR inhibition.
Volume: 5 mL (2.0 ml minimum)
Special instructions: Testing referred to Viracor Eurofins NEWXW#6501
Processing Instructions:
DO NOT SHARE! Centrifuge and transfer 2 mL plasma to sterile, screw top tube.
Shipping/Handling Instructions:
On-campus collections: Tube to 99 or deliver to University Extension Hospital Room EH318
Off-campus collections: DO NOT SHARE! Can be shipped at ambient or frozen temperature Monday through Friday. Specimens shipped at ambient temperature must be received within 96 hrs. of collection.
Reject due to: SST specimens
Performing Location
NI VIRACOR LAB