Sign in →

Test Code LAB1875 Epstein-Barr Virus (EBV), Molecular Detection, PCR, Varies

Additional Codes

EBVPV


Necessary Information


Specimen source is required.



Specimen Required


Submit only 1 of the following specimens:

 

Specimen Type: Fluid

Sources: Spinal fluid, sterile body fluids (peritoneal fluid/ascites, pericardial fluid, pleural fluid/thoracentesis), amniotic, or ocular

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Preferred: Sterile screwcap 5-mL plastic vial

Acceptable: Sterile container

Specimen Volume: 0.5 mL

Collection Instructions: Do not centrifuge.

 

Specimen Type: Fluid

Sources: Respiratory; bronchial washing, bronchoalveolar lavage, nasopharyngeal aspirate or washing, sputum, or tracheal aspirate

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Container/Tube:

Preferred: Sterile screwcap 5-mL plastic vial

Acceptable: Sterile container

Specimen Volume: 1.5 mL

 

Specimen Type: Swab

Sources: Eye and upper respiratory (nasal, throat)

Supplies:

-Culturette (BBL Culture Swab) (T092)

-M4-RT (T605)

Container/Tube: Multimicrobe media (M4-RT) and Eswabs

Collection Instructions: Place swab back into multimicrobe media (M4-RT, M4 or M5)

 

Specimen Type: Bone marrow

Container/Tube: Lavender top (EDTA) only

Specimen Volume: 0.5 mL

Additional Information: Clotted specimens will be rejected.

 

Specimen Type: Tissue

Sources: Brain, colon, kidney, liver, lung, cornea, etc.

Supplies: M4-RT (T605)

Preferred: Multimicrobe medium (M4-RT)

Acceptable: Sterile container containing 1-2 mL of sterile saline or multimicrobe medium (M4-RT, M4 or M5)

Specimen Volume: Entire collection

Collection Instructions: Submit only fresh tissue.


Secondary ID

618306

Useful For

Rapid qualitative detection of Epstein-Barr virus (EBV) DNA in specimens

 

Diagnosis of disease due to EBV

 

This test should not be used to screen asymptomatic patients.

Method Name

Real-Time Polymerase Chain Reaction (PCR)/DNA Probe Hybridization

Specimen Type

Varies

Specimen Minimum Volume

Ocular Fluid, Spinal Fluid: 0.3 mL
Sterile body fluids (peritoneal fluid/ascites, pericardial fluid, pleural fluid/thoracentesis): See Specimen Required
Respiratory Specimens: 1 mL
Tissue: 2 × 2-mm biopsy

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Refrigerated (preferred) 7 days
  Frozen  7 days

Reject Due To

Calcium alginate-tipped swab
Wood swab
Transport swab containing gel
Formalin-fixed and paraffin-embedded tissues
Heat-inactivated specimens
Reject

Reference Values

Negative

Reference values apply to all ages.

Interpretation

Detection of Epstein-Barr virus (EBV) DNA in cerebrospinal fluid (CSF) supports the clinical diagnosis of central nervous system (CNS) disease due to the virus. EBV DNA is not detected in CSF from patients without CNS disease caused by this virus.

Method Description

Viral nucleic acid is extracted by the MagNA Pure automated instrument (Roche Applied Science) from clinical specimens. Primers are directed to the target gene (latent membrane protein). The LightCycler instrument amplifies and monitors by fluorescence the development of target nucleic acid sequences after the annealing step during polymerase chain reaction (PCR) cycling. This is an automated PCR system that can rapidly detect (30-40 minutes) amplicon development through stringent air-controlled temperature cycling in capillary cuvettes. The detection of amplified products is based on the fluorescence resonance energy transfer (FRET) principle. For FRET product detection, a hybridization probe with a donor fluorophore, fluorescein, on the 3' end is excited by an external light source and emits light that is absorbed by a second hybridization probe with an acceptor fluorophore, LC-Red 640, at the 5' end. The acceptor fluorophore then emits a light of a different wavelength that can be measured with a signal that is proportional to the amount of specific PCR product. Melting curve analysis is performed following PCR amplification. Starting at 45° C, the temperature in the thermal chamber is slowly raised to 80° C and the fluorescence is measured at frequent intervals. Analysis of the PCR amplification and probe melting curves is accomplished through the use of LightCycler software.(Unpublished Mayo method)

Day(s) Performed

Monday through Friday

Report Available

Same day/1 to 4 days

Specimen Retention Time

7 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

87798

LOINC Code Information

Test ID Test Order Name Order LOINC Value
EBVPV Epstein-Barr Virus, PCR, Varies 5005-4

 

Result ID Test Result Name Result LOINC Value
EBVS Specimen Source 31208-2
618327 Epstein-Barr Virus PCR 5005-4

Forms

If not ordering electronically, complete, print, and send a Microbiology Test Request (T244) with the specimen.