Test Code GMCSF Granulocyte Monocyte-Colony Stimulating Factor, Plasma
Ordering Guidance
If this test is ordered with CYPAN / Cytokine Panel, Plasma, this test will be canceled as duplicate and CYPAN performed as ordered.
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Lavender top (EDTA)
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions:
1. Immediately after specimen collection, place tube on wet ice.
2. Centrifuge at 4° C, 1500 x g for 10 minutes.
3. Aliquot plasma into plastic vial.
4. Freeze specimen within 2 hours of collection.
Secondary ID
618775Useful For
Measuring the concentration of granulocyte macrophage-colony stimulating factor (GM-CSF) in plasma
Understanding the etiology of chronic inflammatory diseases or infections, when used in conjunction with clinical information and other laboratory testing
Research studies in which an assessment of the GM-CSF response is needed
Method Name
Bead-Based Multiplex Immunoassay
Specimen Type
Plasma EDTASpecimen Minimum Volume
0.3 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma EDTA | Frozen | 21 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Heat-treated specimen | Reject |
Reference Values
<15.0 pg/mL
Interpretation
Elevated granulocyte macrophage-colony stimulating factor (GM-CSF) concentrations could be consistent with the presence of an inflammatory process or infection.
Method Description
Analyte-specific antibodies are precoated onto color-coded magnetic microparticles. Samples are diluted 1:2 in a mixing plate. Then standards, samples, and microparticles are pipetted into wells, and the immobilized antibodies capture the analytes of interest. Unbound substances are washed away while the magnetic microparticles are immobilized. Next, a biotinylated analyte specific antibody cocktail is added to each well. Following a wash to remove any unbound biotinylated antibody, streptavidin-phycoerythrin conjugate (Streptavidin-PE), is added to each well. After removal of unbound Streptavidin-PE and resuspension of the microparticles in buffer, the plate is analyzed using a Luminex FLEXMAP 3D analyzer. A charged-coupled device camera captures an image of each well and data reduction is performed using the XPONENT software.(Unpublished Mayo method)
Day(s) Performed
Wednesday
Report Available
2 to 8 daysSpecimen Retention Time
14 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
83520
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
GMCSF | GM-CSF, P | 97054-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
618775 | GM-CSF | 97054-1 |