Test Code LAB2081 Respiratory Viral Panel by PCR (Includes SARS Coronavirus 2 (COVID-19), Influenza A & B, RSV and other respiratory pathogens)
Additional Codes:
RVP PCR
Includes:
Detection of SARS Coronavirus 2 (COVID-19), Influenza A (H1, 2009 H1 & H3), Influenza B, Respiratory Syncytial Virus(RSV) Type A, RSV Type B, Parainfluenza 1-4, Human Metapneumovirus, Rhinovirus/Enterovirus, Adenovirus, Coronaviruses (HKU1, NL63, OC43 & 229E), Bordetella pertussis, Bordetella parapertussis, Chlamydophila pneumoniae & Mycoplasma pneumoniae
Notes:
NOTE: As of 11/09/2020, RVP testing may only be added-on within 48 hours of collection.
Collection:
Specimen: Nasopharyngeal swabs, nasal aspirates and BAL
Container: Nasopharyngeal (NP) swabs and nasal aspirates – Universal Transport Media. Submit BAL in sterile container
Volume: 4 mL; Minimum 1 mL
Storage/Transport Temperature:
Ship by overnight delivery with frozen cold packs.
Storage Instructions:
Send specimen to Lab immediately after collection. Refrigerate at 2 – 8C or keep on wet ice if specimen cannot be sent immediately.
Turnaround Time (TAT):
Routine or Stat: 3-5 hours
Test Availability:
24 hours a day / 7 days a week
Request Form:
Microbiology – Green Request Form
Send To:
Central Processing – EH318 University Hospital Extension
Reference Interval:
Negative
Interpretive Data:
This assay employs reverse transcription PCR amplification, target specific primer extension and a liquid bead microarray to detect 22 respiratory pathogens.