Test Code LAB1112 Von Willebrand Panel
Additional Codes:
VW PANEL
Includes:
Includes APTT, VIII:C (Factor VIII), VWF Activity (Ristocetin Co-Factor) and Pathologist interpretation
Notes:
VW Antigen and VW multimer are not included in the Von Willebrand Panel and must be ordered separately.
Collection:
Specimen: Blood
Container: Blue Top Tube with 3.2% (0.109 M) buffered Sodium Citrate anticoagulant only
Specimen Volume: 3 (Three) 3.5 mL Must be filled to arrow (Greiner tube Black Disk) or line (BD)
Pediatric Collection:
- 2 (Two) 3.5 mL Must be filled to arrow (Greiner tube Black Disk) or line (BD)
OR
- 3 (Three) 2.0 mL Must be filled to arrow (Greiner tube White Disk) or line (BD)
Notes:
- Samples not filled properly will be rejected (over or under filled).
- If the patient's hematocrit is >55%, call Lab Client Services at 792-0707 to obtain an anticoagulant adjusted tube.
- For collection information and guidance refer to MUSC Laboratory Services Hemostasis / Coagulation Collection Guidelines
Storage Instructions:
Room Temperature: 2 hours Whole Blood
Frozen at or below -20°C: 2 weeks
Note: Frozen samples must be platelet poor plasma aliquoted from primary tube. Label as Na Citrate or blue top plasma.
Turnaround Time (TAT):
Results reported in one week.
Test Availability:
Batched once per week, day varies.
Assay:
2 ml plasma
Send To:
UMC MAIN LABORATORY Specimen Receiving – EH318 University Hospital Extension
Reference Interval:
See individual tests